Solution · 05

300 kWh a year — a number you can see.

A solution page sales can quote to a hotel as it stands.

The situation

The air conditioning runs in an empty room.

The card slot was meant to save energy, but once guests use a piece of paper or a business card instead, the room goes back to permanent power — and the saving is gone.

  • A piece of paper instead of a card, and the saving is worthless

    The card slot was meant to save energy, but it swaps the real question — is anyone in the room — for a fake one: is a card in the slot. Leave the card behind at checkout, or use a piece of paper instead, and the room goes back to permanent power. Our answer is to change the test: not the card, the person.

The norm

A hotel tracks a room’s electricity closely, yet can do nothing about an empty room burning power — because it happens after the guest has left.

Pain points

Paper in the slot

Any stiff card works, so the whole logic is bypassed.

Card left behind

The guest goes out and the lights and air conditioning stay on.

Nothing measured

How much was saved, nobody knows — and nobody can be held to it.

Our solution

Presence takes over, and the data is there.

Presence sensing decides whether the room really has someone in it, and the networked policy cuts the power accordingly. Usage and savings per room are visible in the LMC.

  • Every room’s usage and saving shows up in the LMC

    Presence sensing decides whether the room really has someone in it, and the networked policy cuts the power. Usage and savings for every room and every period go into the LMC platform, comparable by room type and by month. Saving is not a slogan — it can only be signed off once the data is there. Around 300 kWh per room per year is the typical figure; actual results depend on site conditions.

Advantages and differences

ItemThe usual wayLOCK.LINK
How power is drawnCard slot (a paper slip defeats it)Presence sensing + networked policy
Empty-room drawPower stays onCuts off automatically
Measured resultNo dataPer room, inspectable
Retrofit costRewiring needed86-type box, replaced in place

Ultra-low power

Four AA batteries, two years.

The LS02 auto silent lock body is rated at 20 open/close cycles a day and runs ≥2 years. It draws less than a traditional hotel proximity lock — batteries are changed in years, not months.

MetricFigureNote
Standalone standby20 μABest in the industry
Networked standby26 μAPersistent BLE link
Per card unlock50 μAh—
Per phone unlock27 μAhPhone scan or tap to open
Daily total (card)1.5 mAh20 unlocks in 24 h, standby included
Daily total (phone)1.3 mAh20 unlocks in 24 h, standby included
Battery life≥2 yearsFour AA cells, 20 cycles a day

There is also a low-battery warning, raised early enough that nobody is suddenly locked out.

Specs and FAQs

The guest-room energy-saving solution takes over a guest room’s power using presence sensing (infrared and microwave): the room powers up as the guest enters and cuts off after a delay when they leave, ending the hidden waste of a forgotten card and air conditioning in an empty room — around 300 kWh saved per room per year, visible over the network.

Sensing
Infrared + microwave
Presence, not motion
Saving
≈300 kWh / year · room
Derived from PMS data
Cut-off delay
Adjustable · 30 s default
Off automatically on leaving
Guest action
Nothing to learn
Power on entry
Networked metering
Visible in the LMC
Verified with data
Installation
86 box, in place
Mostly no rewiring

Card-slot power vs LOCK.LINK occupancy saving

ItemTraditional card slotLOCK.LINK occupancy saving
How power is drawnCard in the slotPresence sensing, no card
Empty-room drawBurns power if the card stays inOff automatically on leaving
The logicThe card decidesInfrared + microwave judge presence
ResultDepends on guest habitAbout 300 kWh / year · room
Operational dataNoneNetworked, measurable and tunable

Common questions

If a guest lies still, will it cut the power by mistake?

No — it uses presence sensing (infrared and microwave), which still detects a person who is still or asleep, so it does not cut off by mistake.

Where does the 300 kWh a year come from?

It is derived from PMS order data: a room is open 19.6 hours a day while the guest is in it for 11.2, which at 70% occupancy leaves roughly 1,022 idle hours a year — about 340 of them with air conditioning running — corresponding to over 300 kWh of avoided cost per room per year. Once networked, real per-room metering can check it; the figure is deliberately conservative.

Is it hard to retrofit older rooms?

An 86-type back box is replaced in place and most standard rooms need no rewiring; the specifics depend on the boxes and wiring on site.

Can it connect to our existing room control?

It can reach the LMC platform through a LOCK.LINK gateway, or be integrated with your existing room control / PMS on a project basis.